Flat roofs need falls to direct rainwater towards drainage outlets and reduce persistent ponding. A roof described as flat is generally designed with a drainage slope, even if that slope is not obvious from ground level. The required fall depends on the roof assembly, structural deflection, waterproofing system and drainage design.
Why standing water is a problem
Water collecting in low areas can increase the duration of exposure at membrane joints and penetrations. It also adds weight to the roof. Debris may accumulate in ponded areas and restrict outlets further. Some waterproofing systems tolerate standing water better than others, but this does not remove the need for suitable drainage and structural assessment. Persistent ponding may indicate inadequate falls, blocked outlets or movement of the supporting structure.
How to calculate a roof fall
A fall expressed as 1:80 means one unit of vertical drop over 80 units of horizontal distance. For an illustrative 4 m drainage run, the corresponding drop is 50 mm. This is a mathematical example, not a recommended minimum fall. The designer must consider construction tolerances and deflection so the completed roof drains as intended. Follow the actual waterproofing system specification and approved drawings.
How falls are formed
Drainage slopes may be created in the supporting structure, a designed screed or a suitable tapered insulation system. The choice affects roof weight, levels, thermal performance and waterproofing details. Adding a heavy screed to an existing roof without checking its capacity can introduce structural risks. Outlets, upstands, door thresholds and parapets must be coordinated with the finished drainage levels.
Practical example: water collecting beside an outlet
A homeowner notices a persistent puddle on a concrete roof after rain. A specialist checks whether the outlet is obstructed, surveys the surface levels and investigates any signs of deflection. If the outlet is clear but the surrounding roof falls away from it, the repair may require a redesigned drainage detail rather than another coating. Emergency overflow provisions should also be assessed where water could become trapped behind parapets.
Consult the SABS for applicable building and drainage standards and the membrane manufacturer’s technical specifications. Use the area calculator for preliminary roof surface quantities and browse waterproofing specialists. Do not access a wet or structurally suspect roof without appropriate professional safety controls.
Frequently asked questions
No. The roof system, drainage layout and structural design determine the required fall.
Not necessarily. Correct the drainage or structural cause where required.
Only after checking structural capacity, compatibility and the proposed drainage levels.
Related construction questions
Have More Construction Questions?
Explore our South African construction knowledge hub for practical answers about building materials, costs, regulations, construction methods and more.
Browse All Construction Questions