A lintel is a structural member that spans an opening, such as a door or window, and transfers loads to supports on either side. It allows masonry or other construction above the opening to remain supported. The correct lintel depends on the span, loads, support conditions and construction system.
How a lintel carries loads
The lintel acts as a beam or part of a designed composite assembly. Loads above the opening create bending and shear forces, which are transferred to the supporting masonry or frame. The supports must be capable of carrying these reactions. The weight of masonry is only one consideration: floors, roofs and concentrated loads may also influence the design.
Common lintel types
Precast concrete lintels are widely used in masonry construction. Some products rely on masonry built above them to form a composite load-bearing assembly, so installation and temporary propping are important. Reinforced concrete lintels cast in place can be designed for specific conditions. Steel lintels and beams may suit other spans or structural arrangements, with appropriate corrosion and fire protection where required.
What determines lintel size and bearing?
The clear opening width is not the full lintel length. The member needs suitable support at each end, with bearing length and supporting material determined by its design or approved product specification. Do not select a lintel simply because it is longer than the opening. Check load capacity, deflection, orientation, bearing and any required reinforcement or propping. Large openings and concentrated loads warrant professional structural assessment.
Practical example: replacing a window
A homeowner wants to widen a window in an existing masonry wall. The existing lintel may not be suitable for the new opening, and removing masonry can interrupt the load path. A structural engineer should assess the wall, specify the replacement support and determine temporary works before demolition begins. The contractor must follow the approved sequence rather than removing the old lintel first and improvising support afterwards.
For new masonry, coordinate lintels with cavity trays, flashings and insulation where required. Consult the Clay Brick Association and Concrete Manufacturers Association for masonry and precast product guidance. Use the brick calculator to estimate surrounding masonry after deducting openings; it does not size structural lintels.
Frequently asked questions
An ordinary door frame is not automatically designed to carry masonry loads. Use the specified structural support.
Some do. Follow the product instructions and structural design until the assembly has developed adequate strength.
Do not cut a structural lintel without approval. Cutting may damage reinforcement or prestressing and reduce capacity.
Related construction questions
Have More Construction Questions?
Explore our South African construction knowledge hub for practical answers about building materials, costs, regulations, construction methods and more.
Browse All Construction Questions